Serial to Ethernet Converters

Industrial-Grade Serial Device Servers & Modbus Gateways

Don’t let Modbus timeouts and RS485 polling collisions slow down your OT integration. 1500V-3000V optical isolation, Virtual COM drivers and automatic TCP conversion from -40°C to 85°C extremes are all part of our serial device servers.

Hardware Specification Matrix

Verified technical parameters sorted by port density. Select your precise serial configuration below.

Model / SeriesSerial InterfaceEthernet PortsElectrical ProtectionPower & MountingAction
1CH-RS485-ETH1 × RS485 Only1 × RJ452KV Surge Protection9~24V DC | 35mm DINSpecs
1CH-RS232/485/422-ETH (V)1 × 3-in-11 × RJ452KV Surge Protection9~24V DC | DesktopSpecs
2CH-RS485-ETH2 × RS485 Only1 × RJ452KV Surge Protection9~24V DC | DIN-RailSpecs
2CH-RS485-ETH (V)2 × RS485 Only1 × RJ451500V Isolation9~24V DC | DIN-RailSpecs
2CH-RS232/485/422-ETH2 × 3-in-12 × RJ45 (Cascade)2KV Surge Protection9~24V DC | DIN-RailSpecs
4CH-RS485-ETH4 × RS485 Only1 × RJ452KV Surge Protection9~24V DC | DIN-RailSpecs
4CH-RS485-ETH (VI)4 × RS485 Only2 × RJ45 (Cascade)3000V Isolation18~36V DC | DIN-RailSpecs
4CH-RS232/485/422-ETH4 × 3-in-12 × RJ45 (Cascade)2KV Surge Protection9~24V DC | DIN-RailSpecs
8CH-RS485-ETH8 × RS485 Only1 × RJ452KV Surge Protection9~24V DC | DIN-RailSpecs
8CH-RS485-ETH (VI)8 × RS485 Only2 × RJ45 (Cascade)3000V Isolation18~36V DC | DIN-RailSpecs
8CH-RS232/485-ETH8 × 3-in-12 × RJ45 (Cascade)2KV Surge Protection9~24V DC | DIN-RailSpecs
16CH-RS232/485/422-ETH16 × 3-in-14 × RJ45 (Switch)2KV Surge ProtectionAC 220V | 1U RackSpecs
32CH-RS232/485/422-ETH32 × 3-in-14 × RJ45 (Switch)2KV Surge ProtectionAC 220V | 1U RackSpecs

Find Your Exact Serial Server Model

Select your specifications. The system will only show verified hardware matches.

✓ Standard Match

1CH-RS485-ETH

Single port RS485 DIN-rail adapter. Wide 9-24V voltage input, Modbus RTU to TCP support.

View Product Specs

Valtoris Industrial Serial to Ethernet Converter Solution

Whether integrating legacy CNC machines into modern SCADA networks or polling smart meters for energy management, Valtoris device servers provide reliable telemetry across a variety of OT topologies.

Serial to Ethernet Converter SCADA Network Topology
Wide Temperature Reliability

Achieve stable 24/7 operation in harsh cabinets with -40°C to 85°C industrial rating and 2KV surge protection.

Multi-Protocol Flexibility

More than transparent transmission. Natively handle Modbus RTU to TCP conversion and automatic Endianness byte-swapping at the edge.

Comprehensive Support

Enjoy peace of mind with OEM/ODM services, technical assistance, and warranty support. We don’t disappear after shipment.

Valtoris Serial to Ethernet Adapter
High-Speed Performance

Serial baud rates up to 921.6 Kbps and 100M/1000M auto-sensing Ethernet interfaces. Telemetry throughput increases.

Scalable Port Options

Choose from 1, 2, 4, 8, 16, or 32-port models to match your network size. Desktop, DIN-rail, or 1U rack-mount for any installation need.

Isolation Protection

Models with 1500V–3000V optocoupler isolation completely block destructive stray currents and permanently eliminate RS485 ground loops.

Protocol Normalization

Supported Protocols & Legacy PLCs

Stop writing complex PLC socket handling logic. Our serial gateways natively support Modbus RTU to TCP translation, multi-host polling, and Virtual COM mapping for Siemens STEP7, Allen-Bradley, and legacy Modbus instruments.

RAW MODBUS RTU (RS485 IN) 01 04 02 08 AE 3E 08
↓ Active Protocol Translation via Gateway Mode ↓
MODBUS TCP (ETHERNET OUT) ID: 01 | Reg: 40001 | Val: 2222 (0x08AE)
Explore VirCom Utility

Applications of Industrial Serial Device Servers

Discover how Valtoris converters enable reliable telemetry across harsh industrial environments.

What Our Clients Say

Real-world performance verified by industrial automation integrators.

Zero Configuration Headaches

“Tech support walked us through the Virtual COM setup and stayed on the line until our old Wonderware SCADA polled the LAN perfectly. That’s why we return.”

— Robert K., Maintenance Engineer
Eliminated Ground Loop Failures

“We deployed Valtoris 8-port isolated servers across our VFD control panels. 3000V isolation completely stopped the stray voltage spikes that used to fry our comm cards.”

— David C., Electrical Project Manager

Industrial Serial Device Servers Related Resources

Explore practical wiring guides, cable pinouts, and Modbus communication architectures.

Expert Guides to Industrial Serial Device Servers

Expert Guides to Industrial Serial Device Servers

How Do I Choose the Right Serial Device Server for My Needs?
  • Think about the port count (1 to 32), interface type (RS232, RS485, RS422, or mixed), and isolation requirements (1500V to 3000V for noisy environments).
  • Need remote cloud connection? Pick models with MQTT.
  • Do you need network redundancy? Versions with two Ethernet ports.
What Cost Benefits Do Valtoris Serial Servers Offer?
  • Reduce cabling costs by sharing a single network connection with up to 32 devices.
  • Minimize downtime with industrial-grade reliability.
  • Eliminate field service calls through remote diagnostics.
  • Lower inventory costs with multi-function devices that serve as serial servers, Modbus gateways and MQTT gateways.
What Customization Options Does Valtoris Offer?
  • We offer OEM/ODM services such as custom firmware, baud rate customization, protocol support, modified enclosure designs and private labeling. Get in touch with our engineering team to discuss your exact requirements.
How Does Valtoris Provide After-Sales Support and Maintenance?
  • With each purchase you will receive technical documentation, configuration software (VirCom) and web based setup guides.
  • Our engineering team provides email and remote support. We offer warranty support and long term availability of products for re-orders.
Can this solve PLC polling collisions and Modbus Exception errors?
  • Yes. Our true Modbus Gateways feature Smart Caching and Bus Decoupling.
  • Instead of forcing your PLC to sequentially poll 30 slow RS485 devices, the gateway handles the micro-polling locally.
  • Your PLC then reads the aggregated, continuous data instantly via a single Modbus TCP request.

Get a Direct Engineering Quote

Struggling to integrate legacy RS232/RS485 machinery into your modern TCP/IP network? Give us your exact port count and isolation requirements and our engineers will respond with a matched hardware quote within 2 hours.

Request Hardware Quote

Frequently Asked Technical Questions

Will converting RS485 to Ethernet introduce latency and cause my Modbus polling to time out?

A: Standard converters frequently cause timeouts because they wait too long to package serial frames into TCP packets. Valtoris servers eliminate this by providing customizable Frame Packing Thresholds (adjustable from 1 to 255 bytes, or 10ms to 1000ms intervals). This ensures strict Modbus RTU timing compliance across LAN networks.

What is the exact engineering difference between Transparent mode and Modbus Gateway mode?

A: Transparent mode simply chops raw serial bytes into TCP payloads without reading them. True Modbus Gateway mode actively inspects the protocol: it translates Modbus RTU frames into standard Modbus TCP headers. It also starts Slave Register Caching which allows two different SCADA masters to poll the same RS485 sensor simultaneously without bus collision exceptions.

My control room PC runs Windows 11 and has zero physical DB9 serial COM ports. How do I connect?

A: You install our free VirCom Virtual Serial Port driver. It captures the network IP stream and maps it to a virtual local port (e.g., COM5) inside Windows Device Manager. Your legacy software (like older Wonderware or WinCC builds) connects to “COM5” exactly as if a physical copper RS232 cable were strung 500 meters across the plant floor.

When is 3000V Optical Isolation strictly mandatory on an RS485 bus?

A: You must deploy isolated models (Series VI) whenever the RS485 data line crosses between two separate buildings, runs alongside 480V motor feeder cables, or enters Variable Frequency Drive (VFD) cabinets. Any difference in earth ground potential between distant buildings can cause destructive ground loop currents. Our internal 3000V optocouplers physically break that electrical path and protect your central IT switch gear.