16-Port Isolated RS485/422 Rackmount Serial Server | 2kV Isolation

The 16CH-RS485 422-ETH(VI) is an industrial 1U rackmount serial device server engineered for harsh environments, featuring 2 kVAC / 3 kVDC optical isolation across all 16 channels. Its unique features include transparent Modbus RTU/TCP conversion, MQTT cloud data publishing, Moxa Virtual COM Mapping-bridging of RS485/RS422 fieldbuses, and 2 × Gigabit Ethernets.

INSTANT QUOTE
Part No. 16CH-RS485 422-ETH(VI) SKU: IoT-SS111-VI Categories: ,

16-Port 1U Consolidation & Dual 1G Uplinks

Replace 16 separate DIN-rail converters with a single 19-inch 1U rackmount unit featuring copper and fiber Ethernet backhaul.

  • Independent Serial Channels: 16× Isolated RS485/422 ports on 5-pin 5.08mm screw terminals run independent baud rates (600–460,800 bps) simultaneously.
  • Dual-IP Subnet Isolation: Configure the 2× 1G SFP/RJ45 combo ports on separate subnets to isolate local OT traffic from enterprise IT networks.
  • Daisy-Chain Cascading: Link multiple rackmount units via Ethernet cascading mode to save upstream switch ports.
16-Port RS485 RS422 Rackmount Serial Device Server with Dual 1G SFP Fiber and Copper Combo Ports

Drop-In Virtual COM & Fast Modbus Polling

Connect legacy serial equipment to SCADA and Windows hosts without modifying existing software.

  • Moxa RealCOM Compatible: Supports RealCOM_MCP, RealCOM_CCP, and RealCOM_MW virtual COM mapping plus RFC2217 dynamic baud rate control.
  • Modbus Slave Readahead: Pre-fetches and caches up to 32 RTU or 16 ASCII commands per port for sub-10ms Modbus TCP response times.
  • 8-Host Concurrent Access: Allows up to 8 simultaneous TCP Client connections per serial port with Virtual ID conflict mapping.
Modbus RTU to Modbus TCP Gateway Slave Readahead and Moxa RealCOM Virtual COM Port Mapping

Direct Cloud Protocols & Serial Forwarding

Stream serial telemetry directly to cloud brokers or bridge serial buses across IP networks without an edge PC.

  • Native Cloud Ingestion: MQTT client embedded (standard, Alibaba, Huawei, Tencent, OneNet), HTTPD client (GET/POST), WebSocket & DDP/DC.
  • Hardware Serial Forwarding: Forward RS485/422 via Ethernet or move data directly between local COM ports using Pair Connection mode.
  • Encrypted Data Transport: TLS 1.0/1.1/1.2 payload protection using AES/3DES/DES/RC4/RC5/BlowFish encryption (OpenSSL-1.1.1q).
16-Channel RS485 to MQTT Cloud Gateway and Serial-to-Serial Forwarding Architecture

Substation-Grade EMC & Optical Isolation

Built for 24/7 unattended operation in high-interference electrical rooms and industrial plants.

  • 2kV Optical Isolation: Features 2 kVAC / 3 kVDC optical isolation on all serial ports to eliminate ground loops and protect against high-voltage surges.
  • Self-Healing Operation: External hardware watchdog and configurable No-Data Auto-Reboot timer automatically recover stalled connections.
  • Level 4 EMC & Wide Temp: IEC 61000-4 Level 4 ESD (±15kV) and EFT (±4kV) protection in a fanless IP40 metal chassis (-40°C to +70°C).
Industrial 1U Serial Server IEC 61000-4 Level 4 EMC Protection and Hardware Watchdog
ParameterDescription (16CH-RS485 422-ETH(VI))
Software & System
Processor & Watchdog32-bit dual-core ARM Cortex-A8 (up to 800 MHz); External hardware watchdog
Network ProtocolIP, TCP/UDP, ARP, ICMP, DHCP Client, DNS, HTTP, RFC2217, NTP, TELNET, SNMP, TFTP
IP Obtaining & DNSStatic IP / DHCP; DNS supported
User ConfigurationWeb-based configuration (HTTP) and basic network parameter configuration via CONSOLE port
Transparent TransmissionUDP Client, UDP Server, UDP Multicast, TCP Client, TCP Server (up to 8 simultaneous connections per port), RealCOM (MCP/CCP/MW), Pair Connection (Master/Slave)
ModbusModbus RTU/ASCII to Modbus TCP bidirectional conversion; Modbus Over TCP; Slave Readahead (up to 32 RTU or 16 ASCII commands per port); Virtual ID mapping
Cloud & IoT ProtocolsHTTPD Client (GET/POST), WebSocket Client, DDP/DC, MQTT (Standard MQTT, Alibaba Cloud, OneNet Multi-Protocol & IoT Suite, Huawei Cloud, Tencent Cloud)
Framing, Buffers & DelayPacket length (max 1460 bytes) or time-interval framing; Network Buffer: Tx 16 KB / Rx 16 KB; Serial Buffer: Tx 2 KB / Rx 2 KB; Transmission delay <10 ms
Heartbeat & RegistrationTCP Keep-alive mechanism; Customizable heartbeat and registration packet content
Encryption & Access ControlDES, 3DES, AES, RC2, RC4, RC5, BlowFish (OpenSSL-1.1.1q); TLS 1.0/1.1/1.2; Web/SSH access control; IP/MAC filtering
Serial Forwarding & SoftwareDisable, bidirectional, unidirectional forwarding, unidirectional receive; Network management configuration tool & Virtual COM software
Interface & Hardware
1G Ethernet Port2 × 10/100/1000Base-T(X) auto-sensing RJ45 copper ports or 1000Base-X SFP slots optional (Copper: full/half duplex, auto MDI/MDI-X; SFP: 100/1000 Mbps)
Serial PortPort type: 16 × RS485/422 (Optical Isolation: 2 kVAC / 3 kVDC)
Connector: 5-pin 5.08 mm pitch terminal block
Baud rate: 600 ~ 460,800 bps | Data bits: 5, 6, 7, 8 | Stop bits: 1, 2 | Parity: None, Odd, Even, Mark, Space
USB, Console & Button1 × Type-A USB 2.0 (log storage); 1 × RJ45 CONSOLE port (RS232 signal); One-click restart / factory reset button
Status LEDsPower supply indicator, running indicator, alarm, Ethernet port indicator, serial port indicator
Power, Physical & Environmental
Power SupplyInput: AC 85~264V / DC 110~370V | Consumption: <6.5W @ AC220V | Connector: 3-pin AC socket with switch
Mechanical482.6 × 44 × 210 mm (including mounting brackets, excluding connectors); Standard 19-inch 1U rack mount; IP40 metal shell
Working EnvironmentOperating Temp: -40°C ~ +70°C | Storage Temp: -40°C ~ +85°C | Relative Humidity: 5% ~ 95% (non-condensing)
EMC & CertificationIEC 61000-4-2 (ESD): Level 4 (±8kV contact, ±15kV air)
IEC 61000-4-5 (Surge): Level 3 (Power: ±2kV CM/DM; RS485: ±4kV CM/DM; Ethernet: ±6kV CM / ±2kV DM)
IEC 61000-4-4 (EFT): Level 4 (Power: ±4kV; Ethernet & Serial: ±2kV)
Certification: CE, FCC, RoHS
16CH-RS485 422-ETH(VI) Product Datasheet (PDF)
Complete technical specifications, interface parameters, EMC immunity levels, and mechanical dimensions.
1. How do I wire 2-wire RS485 versus 4-wire RS422 on the 5-pin 5.08mm terminal blocks?
Each 5-pin pluggable terminal block on the 16CH-RS485/422-ETH(VI) is numbered 1 to 5 from left to right:
• Pin 1 (T+/A): RS422 Transmit Positive (T+) or RS485 Data A+
• Pin 2 (T-/B): RS422 Transmit Negative (T-) or RS485 Data B-
• Pin 3 (R+): RS422 Receive Positive (R+)
• Pin 4 (R-): RS422 Receive Negative (R-)
• Pin 5 (G): Isolated RS485/RS422 Signal Ground
For 2-wire half-duplex RS485, connect your bus to Pin 1 (A+), Pin 2 (B-), and Pin 5 (G). For 4-wire full-duplex RS422, wire all five pins (T+, T-, R+, R-, and G).
2. How does the 2 kVAC / 3 kVDC optical isolation stop VFD noise and ground loops?
When RS485/422 cables run across different buildings or near high-power VFDs and motors, ground potential differences cause common-mode voltage shifts and ground loop currents that burn out non-isolated transceivers. The 2 kVAC / 3 kVDC optical isolation electrically decouples the serial ports from the internal CPU and Ethernet network. Connect the isolated Signal Ground (Pin 5) to your field reference and tie the rear chassis grounding screw (using a ≥2.5 mm² wire) to your cabinet protective earth for full IEC 61000-4 Level 4 surge/ESD protection.
3. Can I mix RS485 and RS422 devices with different baud rates—or duplicate Modbus Slave IDs—across the 16 ports?
Yes. Each of the 16 Serial Ports is independent, i.e., each Serial port can be different serial modes (RS485 or RS422), protocols (Modbus, TCP/UDP, MQTT, or RealCOM), or baud rates (300bps up to 460,800bps — max baud rates for COM1 and COM9 max. baud rates up to 115,200bps but Serial COM2-8 and Serial COM10-16 as high as 460,800bps). If multiple field devices on different ports share the same factory default address (e.g., Slave ID 1), enable Modbus Virtual ID Mapping to assign unique virtual IDs for SCADA polling without reconfiguring the field instruments.
4. How do I prevent Modbus TCP timeouts when SCADA polls dozens of slow RTU meters through one gateway?
Standard serial gateways queue TCP requests one by one on the slow RTU side, causing SCADA timeouts when polling many power meters or flowmeters. To prevent this, enable Modbus Slave Readahead so that each port can poll and store up to 32 RTU or 16 ASCII commands in local RAM for instant (<10 ms) TCP responses. The Web UI also allows you to fine-tune the Modbus Response Timeout (100 – 9999 ms), Inter-Character Delay (10 – 500 ms), and Inter-Frame Delay (10 – 500 ms) for legacy devices sensitive to RTU timing (t1.5/t3.5).
5. Does this (VI) isolated model support RS232, or how do I choose between (VI) and (V)?
• 16CH-RS485/422-ETH(VI) (This Model): Dedicated to 16× optically isolated RS485/RS422 ports (2 kVAC / 3 kVDC isolation). It does not support RS232 signals.
• 16CH-RS232 485-ETH(V): Provides 16× non-isolated RS232/RS485 ports (no RS422). Choose the (V) model if your cabinet equipment requires 3-wire RS232 (TX, RX, GND) alongside standard RS485.
Order Evaluation Units or Request Volume Project Pricing
Order online for immediate sample testing and PoC validation, or contact our engineering team for volume BOM quotes and direct technical support.
  • Ready to Wire Out of the Box: Includes all 16× 5-pin 5.08mm mating terminal blocks, 19-inch 1U rack ears, and AC power cord.
  • Direct Engineering Support: Pre-sales Modbus/MQTT architecture consultation and hardware warranty.