16-Port RS232/485 Rackmount Serial Server | Dual 1G SFP

The 16CH-RS232 485 -ETH(V) is a 1U industrial rackmount serial device server that enables 16 independent RS232/RS485 channels to communicate to dual Gigabit copper or SFP fiber Ethernet networks. It’s perfect for high-density controller cabinets with drop-in replacement under Modbus RTU/TCP conversion and MQTT cloud publishing as well as Moxa-compatible Virtual Com port mapping.

INSTANT QUOTE
Part No. 16CH-RS232 485-ETH(V) SKU: IoT-SS111-V Categories: ,

16-Port 1U Consolidation & Dual 1G Uplinks

Replace 16 separate DIN-rail converters with a single 19-inch 1U rackmount unit featuring copper and fiber Ethernet backhaul.

  • Independent Serial Channels: 16× RS232/RS485 ports on 5-pin 5.08mm screw terminals run independent baud rates (600–460,800 bps) simultaneously.
  • Dual-IP Subnet Isolation: Configure the 2× 1G SFP/RJ45 combo ports on separate subnets to isolate local OT traffic from enterprise IT networks.
  • Daisy-Chain Cascading: Link multiple rackmount units via Ethernet cascading mode to save upstream switch ports.
16-Port RS232 RS485 Rackmount Serial Device Server with Dual 1G SFP Fiber and Copper Combo Ports

Drop-In Virtual COM & Fast Modbus Polling

Connect legacy serial equipment to SCADA and Windows hosts without modifying existing software.

  • Moxa RealCOM Compatible: Supports RealCOM_MCP, RealCOM_CCP, and RealCOM_MW virtual COM mapping plus RFC2217 dynamic baud rate control.
  • Modbus Slave Readahead: Pre-fetches and caches up to 32 RTU or 16 ASCII commands per port for sub-10ms Modbus TCP response times.
  • 8-Host Concurrent Access: Allows up to 8 simultaneous TCP Client connections per serial port with Virtual ID conflict mapping.
Modbus RTU to Modbus TCP Gateway Slave Readahead and Moxa RealCOM Virtual COM Port Mapping

Direct Cloud Protocols & Serial Forwarding

Stream serial telemetry directly to cloud brokers or bridge serial buses across IP networks without an edge PC.

  • Native Cloud Ingestion: Built-in MQTT Client (Standard MQTT, Alibaba, Huawei, Tencent, OneNet), HTTPD Client (GET/POST), WebSocket and DDP/DC modes
  • Hardware Serial Forwarding: Forward RS232/485 via Ethernet or move data directly between local COM ports using Pair Connection mode.
  • Encrypted Data Transport: TLS 1.0/1.1/1.2 payload protection using AES/3DES/DES/RC4/RC5/BlowFish encryption (OpenSSL-1.1.1q).
16-Channel RS485 to MQTT Cloud Gateway and Serial-to-Serial Forwarding Architecture

Substation-Grade EMC & Zero-Downtime Watchdog

Built for 24/7 unattended operation in high-interference electrical rooms and industrial plants.

  • Self-Healing Operation: External hardware watchdog and configurable No-Data Auto-Reboot timer automatically recover stalled connections.
  • Wide AC/DC Power Input: Internal AC 85–264V / DC 110–370V power supply (<6.5W consumption) with standard 3-pin switched socket.
  • Level 4 EMC & Wide Temp: IEC 61000-4 Level 4 ESD (±15kV) and EFT (±4kV) protection in a fanless IP40 metal chassis (-40°C to +70°C).
Industrial 1U Serial Server IEC 61000-4 Level 4 EMC Protection and Hardware Watchdog
ParameterDescription (16CH-RS232 485 -ETH(V))
Software & System
Processor & Watchdog32-bit dual-core ARM Cortex-A8 (up to 800 MHz); External hardware watchdog
Network ProtocolIP, TCP/UDP, ARP, ICMP, DHCP Client, DNS, HTTP, RFC2217, NTP, TELNET, SNMP, TFTP
IP Obtaining & DNSStatic IP / DHCP; DNS supported
User ConfigurationWeb-based configuration (HTTP) and basic network parameter configuration via CONSOLE port
Transparent TransmissionUDP Client, UDP Server, UDP Multicast, TCP Client, TCP Server (up to 8 simultaneous connections per port), RealCOM (MCP/CCP/MW), Pair Connection (Master/Slave)
ModbusModbus RTU/ASCII to Modbus TCP bidirectional conversion; Modbus Over TCP; Slave Readahead (up to 32 RTU or 16 ASCII commands per port); Virtual ID mapping
Cloud & IoT ProtocolsHTTPD Client (GET/POST), WebSocket Client, DDP/DC, MQTT (Standard MQTT, Alibaba Cloud, OneNet Multi-Protocol & IoT Suite, Huawei Cloud, Tencent Cloud)
Framing, Buffers & DelayPacket length (max 1460 bytes) or time-interval framing; Network Buffer: Tx 16 KB / Rx 16 KB; Serial Buffer: Tx 2 KB / Rx 2 KB; Transmission delay <10 ms
Heartbeat & RegistrationTCP Keep-alive mechanism; Customizable heartbeat and registration packet content
Encryption & Access ControlDES, 3DES, AES, RC2, RC4, RC5, BlowFish (OpenSSL-1.1.1q); TLS 1.0/1.1/1.2; Web/SSH access control; IP/MAC filtering
Serial Forwarding & SoftwareDisable, bidirectional, unidirectional forwarding, unidirectional receive; Network management configuration tool & Virtual COM software
Interface & Hardware
1G Ethernet Port2 × 10/100/1000Base-T(X) auto-sensing RJ45 copper ports or 1000Base-X SFP slots optional (Copper: full/half duplex, auto MDI/MDI-X; SFP: 100/1000 Mbps)
Serial PortPort type: 16 × RS232/485 | Connector: 5-pin 5.08 mm pitch terminal block
Baud rate: 600 ~ 460,800 bps | Data bits: 5, 6, 7, 8 | Stop bits: 1, 2 | Parity: None, Odd, Even, Mark, Space
USB, Console & Button1 × Type-A USB 2.0 (log storage); 1 × RJ45 CONSOLE port (RS232 signal); One-click restart / factory reset button
Status LEDsPower supply indicator, running indicator, alarm, Ethernet port indicator, serial port indicator
Power, Physical & Environmental
Power SupplyInput: AC 85~264V / DC 110~370V | Consumption: <6.5W @ AC220V | Connector: 3-pin AC socket with switch
Mechanical482.6 × 44 × 210 mm (including mounting brackets, excluding connectors); Standard 19-inch 1U rack mount; IP40 metal shell
Working EnvironmentOperating Temp: -40°C ~ +70°C | Storage Temp: -40°C ~ +85°C | Relative Humidity: 5% ~ 95% (non-condensing)
EMC & CertificationIEC 61000-4-2 (ESD): Level 4 (±8kV contact, ±15kV air)
IEC 61000-4-5 (Surge): Level 3 (Power: ±2kV CM/DM; RS485: ±4kV CM/DM; Ethernet: ±6kV CM / ±2kV DM)
IEC 61000-4-4 (EFT): Level 4 (Power: ±4kV; Ethernet & Serial: ±2kV)
Certification: CE, FCC, RoHS
16CH-RS232 485 -ETH(V) Product Datasheet (PDF)
Complete technical specifications, interface parameters, EMC immunity levels, and mechanical dimensions.
1. Does the server include built-in 120Ω RS485 termination resistors, or do I need external resistors?
The unit features built-in onboard RS485 termination resistors (defaulting to disconnected/OFF from the factory). If the serial server is located at the physical end of a long RS485 bus and experiences signal reflections or CRC errors, you can enable the internal termination resistor for specific ports by opening the chassis and moving the corresponding port jumper cap to the ON position, or wire an external 120Ω resistor across the A+ and B- terminal pins.
2. Which TCP/UDP ports are reserved by the system when configuring firewall rules or local sockets?
Ports 22, 80, 443, 4500, 4800, 57050, 57051, 57850, and 57851 are reserved internally by the operating system for Web management, console access, and Virtual COM control channels. When assigning Local Ports or Destination Ports for your 16 serial channels (valid range: 1–65535, default starting at 31001), do not use these reserved port numbers to avoid socket conflicts.
3. How can I recover Web UI access if I forget the admin password without wiping my 16-port configuration?
You do not need to factory-reset the device. First, log into the Web UI using the read-only guest account (Username: none, Password: none) and check the Device Information page to find the MAC Address 1 (eth1). Then log in with the super-administrator account using Username admin and the last 6 characters of the eth1 MAC address as the password to reset your regular user password while keeping all serial configurations intact.
4. How do I stop fragmented Modbus frames or garbage bytes on noisy RS485 lines?
In the Serial Port Configuration menu, configure the Packet Interval (0–255 ms) and Packet Length (0–1460 bytes) so the server waits for a complete serial frame before wrapping it in an Ethernet packet. Enable Header/Trailer Framing Mode (start and end bytes user configurable 0x00 to 0xFF). If electrical noise is creating false bytes on idle lines, any data outside valid frame boundaries is automatically discarded.
5. What is the hardware difference between the 16CH-ETH(V) and 16CH-ETH(VI) models?
• 16CH-RS232 485 -ETH(V) (This Model): Provides 16× non-isolated RS232/RS485 ports (3-wire RS232 or 2-wire half-duplex RS485). Ideal for standard equipment inside a shared-ground cabinet.
• 16CH-RS485 422-ETH(VI): Provides 16× optically isolated RS485/RS422 ports with 2 kVAC / 3 kVDC isolation (no RS232). Choose the (VI) model if you require 4-wire RS422 or run long outdoor cables near high-voltage VFDs and motors.
Order Evaluation Units or Request Volume Project Pricing
Order online for immediate sample testing and PoC validation, or contact our engineering team for volume BOM quotes and direct technical support.
  • Ready to Wire Out of the Box: Includes all 16× 5-pin 5.08mm mating terminal blocks, 19-inch 1U rack ears, and AC power cord.
  • Direct Engineering Support: Pre-sales Modbus/MQTT architecture consultation and hardware warranty.